  • Zourari K, Peppa V, Ballester F, Siebert FA, Papagiannis P (2014). 
    Brachytherapy structural shielding calculations using Monte Carlo generated, monoenergetic data. Med Phys (2012) 41 (2014), 043901; doi:10.1016/j.ejmp.2015.05.010
  • Murray L, Henry A, Hoskin P, Siebert FA, Venselaar J on behalf of the PROBATE group of the GEC ESTRO. 
    Second primary cancers after radiation for prostate cancer: A systematic review of the clinical data and impact of treatment technique. Radiother Oncol 110:213-28 (2014).   doi:10.1016/j.radonc.2013.12.012
  • Pujades M del C, Granero D, Vijande J, Ballester F, Perez-Calatayud J, Papagiannis P, Siebert FA 
    Air-kerma evaluation at the maze entrance of HDR brachytherapy facilities. J. Radiol. Prot. 34 (2014) 741–753. http://dx.doi.org/10.1088/0952-4746/34/4/741
  • Kirisits C, Rivard MJ, Baltas D, Ballester F, De Brabandere M, van der Laarse R, Niatsetski Y, Papagiannis P, Paulsen Hellebust T, Perez-Calatayud J, Tanderup K, Venselaar JLM, Siebert FA. Review of clinical brachytherapy uncertainties: Analysis guidelines of GEC-ESTRO and the AAPM. Radiother Oncol, (accepted for publication in 08.11.13) doi:10.1016/j.radonc.2013.11.002
  • Salembier C, Rijnders A, Henry A, Niehoff P, Siebert FA, Hoskin P. 
    Prospective multi-center dosimetry study of low-dose Iodine-125 prostate brachytherapy performed after transurethral resection. Journal of Contemporary Brachytherapy 2013;5,2:63-69
  • Murray L, Henry A, Hoskin P, Siebert FA, Venselaar J on behalf of the BRAPHYQS/PROBATE group of the GEC ESTRO. 
    Second primary cancers after radiation for prostate cancer: A review of data from planning studies.Radiation Oncology 2013, 8:172. The publication fee for this paper was sponsored by Varian Medical Systems doi:  10.1186/1748-717X-8-172
  • Hoskin PJ, Colombo A, Henry A, Niehoff P, Paulsen Hellebust T, Siebert FA, Kovacs G. 
    GEC/ESTRO recommendations on high dose rate afterloading brachytherapy for localised prostate cancer: An update: Radiother Oncol (2013) 2013 Jul 19. S1538-4721(13)00298-5 http://dx.doi.org/10.1016/j.radonc.2013.05.002
  • De Brabandere M, Al-Qaisieh B, De Wever L, Haustermans K, Kirisits C, Moerland MA, Oyen R, Rijnders A, Van den Heuvel F, Siebert FA. 
    CT and MRI based seed localization in post-implant evaluation of permanent prostate brachytherapy. Brachytherapy 13 (2013) S1538-4721 http://dx.doi.org/10.1016/S0167-8140(15)32486-5
  • Siebert, FA, Venselaar J, Hellebust-Paulsen T, Papagiannis P, Rijnders A, Kirisits C, Rivard M. 
    Dose-to-water calibration from the end-user perspective. Metrologia 49 (2012) S249–S252 http://dx.doi.org/10.1088/0026-1394/49/5/S249
  • Perez-Calatayud J, Ballester F, Das RK, DeWerd LA, Ibbott GS, Meigooni AS, Ouhib Z, Rivard MJ, Sloboda RS, Williamson JF. 
    Dose calculation for photon-emitting brachytherapy sources with average energy higher than 50 keV: Report of the AAPM and ESTRO. Med Phys 39 (2012) 2904-2929 http://dx.doi.org/10.1118/1.3703892 Full report with consensus datasets https://www.aapm.org/pubs/reports/RPT_229.pdf
  • De Brabandere M, Haustermans K, Van den Heuvel F, Hoskin P, Siebert FA. 
    Prostate post-implant dosimetry: interobserver variability in seed localization, contouring, and fusion. Radiother Oncol 104 (2012) 192–198 http://dx.doi.org/10.1016/j.radonc.2012.06.014
  • DeWerd LA, Ibbott GS, Meigooni AS, Mitch MG, Rivard MJ, Stump KE, Thomadsen BR, Venselaar JLM.
    A dosimetric uncertainty analysis for photon-emitting brachytherapy sources: Report of AAPM Task Group No. 138 and GEC-ESTRO. Med Phys38 (2011) 782-801 https://www.aapm.org/pubs/reports/RPT_138.pdf
  • Papagiannis P, Baltas D, Granero D, Pérez-Calatayud J, Gimeno J, Ballester F, Venselaar JLM. 
    Radiation transmission data for radionuclides and materials relevant to brachytherapy facility shielding. Med Phys 35 (2008) 4898-4906  http://dx.doi.org/10.1118/1.2986153
  • Siebert FA, De Brabandere M, Kirisits C, Kovács G, Venselaar J. 
    Phantom Investigations on CT Seed Imaging for Interstitial Brachytherapy. Radiother Oncol 85 (2007) 316-323 http://dx.doi.org/10.1016/j.radonc.2007.04.036
  • Roué A, Venselaar JLM, Ferreira IH, Bridier A, Van Dam J. 
    Development of a TLD mailed system for remote dosimetry audit for 192Ir HDR and PDR sources. Radiother Oncol 83 (2007) 86-93 http://dx.doi.org/10.1016/j.radonc.2007.02.011
  • Kirisits C, Siebert FA, Baltas D, De Brabandere D, Paulsen Hellebust T, Berger D, Venselaar J. 
    Accuracy of volume and DVH parameters determined with different brachytherapy treatment planning systems. Radiother Oncol 84 (2007) 290-297 http://dx.doi.org/10.1016/j.radonc.2007.06.010
  • Roué A, Ferreira IH, Van Dam J, Svensson H, Venselaar JLM. 
    The EQUAL-ESTRO audit on geometric reconstruction techniques in brachytherapy. Radiother Oncol 78 (2006) 78-83 http://dx.doi.org/10.1016/j.radonc.2005.12.004